Monitor Installation

7-5

Mounting the Monitor to the Manhole
Rim

Mount the monitor to the manhole rim using the monitor bracket in

the following way:
1. Determine the appropriate location to mount the monitor

bracket to the inside of the iron manhole rim. Consider the

following when selecting the proper location:

Select a location that will allow for easy removal of the

monitor during service visits using the mounting bracket

(extension handle).

Select a location that exhibits only a minimal potential for

experiencing surcharge conditions.

Select a location that will prevent the manhole lid from

potentially damaging the monitor during removal or when

rotating in the opening.

Select a location that will allow personnel to enter/exit the

manhole without removing monitor.

2. Hold the keyhole at the top end of the bracket against the lower

inner rim of the manhole, and mark the location for the

stainless steal stud through the keyhole in the bracket. Make

sure there will be enough room to lift the bracket up and over

the stud when installed.

3. Drill a hole(s) into the manhole rim 1 inch deep using a

5/16-inch carbide-tipped drill bit.

Note:

Consider starting the hole using smaller bits to

make pilot holes and increasing up to a 5/16-inch bit. In

addition, spray cutting oil or another lubricant into the hole

while drilling and tapping.