Configuration and Activation 6-15

from the sensor face to the bottom of the pipe. This (default)

setting effectively represents the vast majority of pipe/flow

conditions. Therefore, ADS strongly recommends selecting this
option for most applications.

Blanking (override)

Enter the distance from the face of the

ultrasonic depth sensor within which to ignore data potentially

representing erroneous readings. Use this option in place of the
auto-blanking

option (above) to designate a distance greater

than

5 percent of the range from the face of the sensor to the

bottom of the pipe. Do not choose a distance shorter than 5

percent of the range. ADS recommends using this option only
when spikes in the data are occurring beyond the 5 percent
range and under direct consultation with an ADS
representative.

Pipe Height

This field represents the height of the pipe in

which the sensor is installed. This parameter is not editable
from this location.

Editing the Velocity Device

Edit the velocity device in the following way, and then click on the
OK

button when complete:

Edit Velocity Device Properties dialog