Connectors, Power, Internal power – ADS Environmental Services FlowShark QR 775003 A2 User Manual

Page 52

Advertising
background image

2-10

ADS FlowShark IS Manual

Connectors

Connectors located on top of the monitor receive the following

cabling and components:

IS ultrasonic depth sensor (ADS p/n 106186A)

IS Doppler velocity sensor (ADS p/n 106194A)

IS pressure depth sensor (ADS p/n 3754-0001/0002/0003)

Communication cable for either on-site (ADS p/n 106228A) or

remote (ADS p/n 106227) communications and external power

supply

Air pressure valve (for testing purposes only)

The connectors are keyed to ensure that only the proper sensor or

communication cable can be connected to each port.

Power

The FlowShark IS flow monitor can receive power internally or

externally.

Internal Power

Internal power is supplied to the FlowShark IS flow monitor by an

IS 9-volt battery pack (ADS p/n 106152A) or an IS 12-volt battery

pack (ADS p/n 8000-0043-01/02). The battery pack resides within

the FlowShark IS enclosure and powers operations and sustains the

monitor memory (RAM) through the power supply on the processor

board. The voltage supplied by the IS battery pack is regulated by

the Voltage Regulator board for intrinsically-safe monitor

operation. The user receives a warning when the voltage from the

internal IS battery pack drops below 6.5 volts.

Note:

ADS offers a conversion kit (p/n 5000-0780-01) to

upgrade an existing FlowShark IS monitor from a 9-volt

battery pack to a 12-volt battery pack.

Advertising