ADS FlowShark IS Manual

Note:

Some desiccant may be reused following a special

process designed to remove the moisture from the beads.

Please consult the desiccant manufacturer for instructions

on performing this procedure, when applicable.

Replacing EMU Components

If a component in the EMU is not functioning, perform the

following procedures (as applicable) to replace the faulty

component.

Note:

ADS allows trained field crews to replace the

quad-band GSM/GPRS wireless modem, SIM, and EMU

battery pack within the EMU box.

Warning:

DO NOT open the Communication

Interface/Barrier (ADS p/n 106226) Box in the field under

any circumstances. Do not attempt any component level

repair.

Accessing the EMU for Maintenance Activities

Access the EMU from the enclosure and open the EMU to access

the component(s) requiring replacement in the following way:
1. Open or remove the cover from the enclosure in which the

EMU is housed.

2. Remove the EMU from the enclosure by releasing the fasteners

securing the EMU to the panel inside the enclosure.

3. Loosen the 4 large plastic screws on the cover of the EMU and

remove the cover. Carefully set the cover aside to avoid

damage and prevent dirt from contacting the gasket on the lid.

4. Refer to one or more of the following sections to perform

modem, battery, or SIM replacement.