Band mount – ADS Environmental Services FlowShark QR 775003 A2 User Manual

Page 95

Advertising
background image

3-38

ADS FlowShark IS Manual

Sensors mounted using a ¾-band mount in the pipe with and without silt

15. Measure the physical offset for the pressure depth sensor (the

vertical distance from the bottom of the pressure depth sensor

to the bottom, center of the pipe).

Note:

This value will be necessary when configuring the

monitor using the Profile software.

16. Run the sensor cables from the sensor location in the pipe to

the monitor location in the manhole according to the

instructions in Securing the Sensor Cables in the Pipe and
Manhole

on page 3-43.

½-Band Mount

Perform the following procedure to mount the Doppler velocity

sensor and pressure depth sensor (when applicable) in a pipe using

the ½-band mount:
1. Use a hacksaw to cut the band to the appropriate length. Cut the

band so that, when installed, it will run almost completely down

the left side of the pipe.

2. Determine the best location on the band to mount the Doppler

velocity sensor. The sensor should mount as close as possible

to the bottom of the band, making sure the sensor will be both
above

the silt level and below the flow surface once installed.

Advertising