Mounting the pressure depth sensor – ADS Environmental Services FlowShark QR 775003 A2 User Manual

Page 77

Advertising
background image

3-20

ADS FlowShark IS Manual

2. Secure the sensor cable to the ring. Refer to Securing the

Cables to the Ring

on page 3-21 for instructions on properly

securing the cable.

Note:

If the installation includes a pressure depth sensor,

wait to secure the sensor cables until both sensors are

installed on the ring.

Mounting the Pressure Depth Sensor

Mount the pressure depth sensor to the ring in the following way:
1. Orient the ring so that the ultrasonic depth sensor is directly on

top. If an ultrasonic depth sensor is not in use, make sure the

spreader assembly is directly on top.

2. Use two 4-40 x 5/16-inch

stainless steel screws (do not

substitute any other screws) to mount the pressure depth sensor

on the bottom inside of the ring with the pointed end of the

sensor facing upstream. Mount the pressure depth sensor about

2 inches to the left of the velocity sensor (when present).

Mounting the pressure depth sensor to the ring

3. Secure the sensor cable to the ring. Refer to Securing the

Cables to the Ring

on page 3-21 for instructions on properly

securing the cable.

Advertising