Configuration and Activation 6-19

Access the ADS website at www.adsenv.com on the

Internet.

Select ADS Environmental Services > Support > Client
Services

.

Click on the Download pressure coefficients… link.

Right-click on the year in which the sensor was

manufactured, and select the Save Target As option.

Rename the file to reflect the following format:
pressure.xx

, where xx represents the last two digits of the

year in which the sensor was manufactured. Remove the
.txt extension!

Save the file to the appropriate location in the local file

system.

Pipe Height

This field displays the pipe height at the monitor

location. This parameter is not editable from this location.

Physical Offset

Enter the vertical distance from the top of

the pressure depth sensor to the bottom center of the pipe. ADS

recommends measuring this distance manually during the

monitor installation or confirmation process. Profile defaults to
0 inches

.

Electronic Offset

Enter the difference that exists between

the pressure depth sensor readings and the manually measured

depth. The default offset is 0 inches.

Editing the MLI Device

Typically, the MLI device does not require editing. However, if the

monitor will be supporting activities such as event notification or

dual data rates, refer to the Profile User’s Guide (#950015**) for

detailed instructions on properly setting the applicable parameters.