ADS Environmental Services FlowShark QR 775003 A2 User Manual

Page 218

Advertising
background image

A-2

ADS FlowShark IS Manual

Internal Power

One ADS 9-volt or 12-volt IS alkaline battery pack
powering the monitor and one ADS non-IS 12-volt
alkaline battery pack powering the External
Modem Unit.

Battery Life

Monitor (9-volt battery pack): 9-12 months at a
15-minute sample rate with weekly
communications.

Monitor (12-volt battery pack): 11-15 months at a
15-minute sample rate with weekly
communications.

EMU: 2-3 months at a 15-minute sample rate
with weekly communications.

Note: Actual battery life will vary depending on
operating temperature and frequency of
communications.

External Power

Option

Requires an external, low-noise DC power source
providing a minimum of 12 volts at 1 amp

Connectors

U.S. MIL-C-26482 series 1, for environmental
sealing, with gold-plated contacts and interfacial
seals

Inputs and

Outputs

IS Ultrasonic depth sensor input

IS Doppler velocity sensor input

IS Pressure depth sensor input

IS Communication/External Power input

Air pressure valve (for testing purposes only)

Approvals

Hazardous Area – approved for use in Class I,
Div. 1, Group C&D areas, in US via QPS/UL Cert,
and in Zone 0 IIG areas in the EU via SIRA/ATEX

Advertising