System Overview

2-13

Ultrasonic depth sensor sending signals to flow surface to determine range

Quadredundancy

Each ultrasonic depth sensor contains four ultrasonic transducers for

taking readings to give the sensor quadredundancy, which ensures

greater sensor reading reliability. To take a reading, one transducer

transmits a sound wave while a second transducer listens for the

returning echo. Each transducer has its own electronic circuitry and

dedicated wiring for true redundancy.

Ultrasonic Depth Processing

The standard method for processing ultrasonic depth involves firing

the sensor once to take readings for predefined transducer pairs.

The monitor performs a detailed analysis of all the returning echoes

that involves amplifying the good readings and attenuating the false

and multiple echoes representing noise and other erroneous

readings. It then discards the questionable data, averages the good

readings to arrive at a final reading for each of the designated pairs,

and logs the final readings in the monitor memory for availability

during data collection activities.