Installing the ring in the pipe – ADS Environmental Services FlowShark QR 775003 A2 User Manual

Page 79

Advertising
background image

3-22

ADS FlowShark IS Manual

addition, make sure the connector-end of the sensor is not

kinked, does not contain moisture, and includes an

attached dryer tube filled with active blue desiccant.

4. Use the diagonal cutters to cut off the excess portion of the

cable ties.

Installing the Ring in the Pipe

The ring must fit securely in the pipe with the sensors properly

positioned to ensure the most accurate monitoring results. Install the

ring in the pipe in the following way:
1. Examine the pipe for possible obstructions to the flow or issues

that may inhibit proper ring installation.

2. Adjust the ring size to slightly less than the pipe diameter

before placing the ring in the pipe by turning the spreader

mechanism adjustment nut clockwise.

3. Place the ring in the input pipe at least 12 inches upstream from

the manhole or edge of the pipe with the sensors facing

upstream toward the oncoming flow. It must be located far

enough upstream from the manhole to minimize the effect of

the draw-down caused by a possible drop in the manhole invert.

Installing the ring at least 12 inches upstream from the manhole invert