C h a p t e r 5 external power, External power – ADS Environmental Services FlowShark QR 775003 A2 User Manual

Page 124

Advertising
background image

5-1

C H A P T E R 5

External Power

The ADS

®

FlowShark

®

IS system (monitor and EMU) can receive

power from an external DC power source connected to the EMU

(ADS p/n 3800-0148EP). However, any connection of external

power to the monitor must occur through an EMU for compliance

with IS certifications.
ADS recommends using external power at sites where the monitor

is operating at fast sample rates, frequent wireless communication is

expected, and/or the monitor will be installed for several years.

Using a single DC source to power both the EMU and the monitor

can be cost effective because it eliminates the need for both the IS

battery pack and the EMU alkaline pack.

Note:

When installing an externally-powered EMU, ADS

recommends locating the EMU as close as possible to the

power source to maximize the net power available to the

EMU.

The following FlowShark IS models support external power:

5000-IS1

5000-IS1-US

Note:

Neither model provides backup power in the event

of an external power source interruption. The monitor will

not lose data: however, it will stop taking readings until

power is restored.

Advertising