ADS Environmental Services FlowShark QR 775003 A2 User Manual

Page 115

Advertising
background image

4-12

ADS FlowShark IS Manual

5. Terminate the 12 wires into the orange connector in the

following way using the ⅛-inch flat screwdriver. This

information also displays on a label affixed to the inside cover

of EMU box. Make sure all screws are tight.

Terminal

Color of Wire

1

Yellow

2

Small Blue

3

Small Black

4

White

5

Small Red

6

Small Green

7

Brown

8

Orange

9

Large Red

10

Large Blue

11

Large Black

12

Large Green with Bare

Shield drain wire

Note:

The wires can become loose while moving the

cable. Therefore, after terminating the wires, verify once

again that each wire is secure.

6. Plug the connector into the corresponding port on the black

Communication Interface/Barrier Box, and then pull back the

excess cable from outside of the EMU.

Note:

The port on the Communication Interface/Barrier

Box may be difficult to access because of the close

proximity of other components, such as the bracket holding

the modem. Therefore, it may be necessary to remove the

box from the EMU before attaching the orange connector.

Release the box from the back plate of the EMU by

grasping the rear edge of the box (next to the back plate)

and gently, but firmly, pulling to release the Velcro

®

grips.

After seating the orange connector, verify that all

connections to the Communication Interface/ Barrier Box

are secure and reseat the box onto the Velcro.

Advertising