Sensor Installation and Connection 3-29

Mounting the Ultrasonic Depth Sensor

Two special installation methods are available for mounting the

ultrasonic depth sensor:

Standard Ultrasonic Mount

This option, the most common

method employed today, is used for mounting the ultrasonic

depth sensor in the pipe during special installations.

Surcharge Mount

This option primarily is used for

mounting a ultrasonic depth sensor in a manhole at a site where

the flow continually occurs within 2 inches of the top of the

pipe or a site at which a pressure sensor is not available and
surcharges

frequently occur. Surcharges are conditions where

the flow completely fills the pipe and extends up into the

manhole.

Standard Ultrasonic Mount

Mount the ultrasonic depth sensor using this method in the

following way:

Note:

Handle the ultrasonic depth sensor with care, and

do not expose it to extreme temperatures for an extended

period of time. Keep the sensor in its protective packaging

until it is time for installation.

1. Position the sliding ultrasonic plate in the center apex of the

pipe, and scribe a mark on both sides of the ultrasonic plate.

2. Center the 12-inch mounting band, allowing the band to extend

about 4 inches beyond each side of the scribed location.

3. Conform one end of the curved band to the pipe configuration,

and spot drill to mark the bolt location.

4. Remove the curved band, drill an anchor bolt hole, and gently

tap a ¼-inch x 2 ¼-inch anchor bolt into the hole.

5. Mount the curved band to the anchor bolt through the pre-

drilled hole on the band, and hand-tighten a nut with washer to

the anchor bolt to secure the band.