Run the Preloaded Diagnostic Tests

User I/O

Run the User I/O Test

Perform the following steps to execute the test for the Stratix GX device
user I/O.

1.

Set all of the Stratix GX user dipswitches (S11) to 0.

2.

Press GX_CLR (S14) to reset the design. When the pushbutton is
pressed, the GX_CLR LED (D16) illuminates. When you release the
pushbutton, the 7-segment display (D9) shows 00.

3.

Press the Stratix GX channel pushbutton switches, Stratix_GX_PB_0
(S2) for up and Stratix_GX_PB_1 (S3) for down. The channel
numbers on the Stratix GX 7-segment display (D9) increment and
decrement as you press S2 and S3, respectively.

4.

Press S14 once.

5.

Press S2 three times. D9 displays 03.

6.

Press S3 four times. D9 displays 99.

7.

Press the Stratix GX volume pushbutton switches, Stratix_GX_PB_2
(S4) for up and Stratix_GX _PB_3 (S5) for down. As you press S4
and S5, the number of Stratix_GX LEDs (D10-15) that are
illuminated should increment and decrement, respectively.

8.

Press S14 once.

9.

Press S4 six times. All of the Stratix_GX LEDs illuminate.

10. Press S5 six times. All of the Stratix_GX LEDs turn off.

11. Using the Stratix GX user dipswitches (S11), enter the binary

number 15.

a.

Set dipswitches 4-1 to 1.

b.

Set dipswitch 7 to the up position and then to the down
position to enter the value. D9 displays the number 15.

12. Enter the binary number 127.

a.

Set dipswitches 7-1 to 1.

b.

Set dipswitch 8 to the up position and then to the down
position to enter the value. D9 displays the number 99.