Altera High-Speed Development Kit, Stratix GX Edition User Manual

Page 73

Advertising
background image

Altera Corporation

Quartus II Version 3.0

5–29

Perform the Production Diagnostic Tests

Nios-Based Tests

Checking Written Data:
Test Done: Goodbye...

#77153008
lan16_all_flash4_pcb_revb
+

16. Press reset (Stratix_PB_0) to stop the test.

17. Press Ctrl + C in the shell to exit the test program.

18. If this test passes, write the word “PASS” in the column under

Stratix in the row Stratix Nios On-Board Flash and Nios EPC16
Flash in the worksheet.

10/100 Ethernet Network-Interface Card I/O Interface (Stratix
Nios PROTO1 IO)

For this test, perform the following steps.

1.

Change the programming file for the Stratix device to the
st_1s40.sof

file. Wait until the checksum field is updated.

2.

Turn on the Program/Configure option for the Stratix device.

3.

Click Start. When configuration is complete, the S_CONF_DONE
LED illuminates.

4.

Choose Programs > Altera > SOPC Builder <version> > SOPC
Builder SDK Shell

(Windows Start menu).

5.

Change to the Nios SOFs directory by typing the following
command:

cd /Stratix_GX_kit/Test_designs/Nios_test_designs/

Nios_sofs

r

6.

Type

nr -t

r to open a terminal window that connects to COM 1.

7.

Press the Enter key twice in the terminal window. You should be at
a Nios prompt.

8.

Confirm that you are connected to the Nios processor running on
the board by pressing the Enter key a few times in the terminal
window to display the processor’s memory contents.

Advertising