Perform the Standard Tests

High-Speed Development Kit, Stratix GX Edition User Guide

9.

Repeat the process (press reset, move the card, and press start) for
connector J45. LED2 illuminates.

10. Repeat the process once more for connector J38. LED3 illuminates.

LED4 indicates that the test is running. LED5 is the error signal.

11. Press the reset pushbutton switch (GX_CLR).

12. Press the start pushbutton switch (Stratix_GX_PB_0).

13. Inject an error by pressing Stratix_GX_PB_2 (S4) once. The number

01 displays on the Stratix GX 7-segment display (D9) and Stratix GX
LED5 illuminates.

14. Press start and then reset three times to insure that the test is

working.

15. Inject two more errors by pressing Stratix_GX_PB_2 (S4) twice. 03

displays on the Stratix GX 7-segment display (D9).

16. If all of these tests pass, write the word “PASS” in the column under

Stratix GX in the row Stratix GX SFP XCVR in the worksheet.

Gigabit Transceivers with XPAK Interface (Stratix GX XPAK
XCVR)

For this test, perform the following steps.

1

This test requires an XPAK module, which is not included with
the kit.

1.

Change the XCVR setting to XPAK by setting the Stratix GX user
dipswitch 6 to the down position and dipswitch 5 to the up position.

2.

Press the reset button (GX_DEV CLR) to initialize the design. The
GX_DEV_CLR LED illuminates.

3.

Press start (GX PB0). Several LEDs illuminate.

LED0 is the match LED

LED1 is the channel synchronization LED

LED2 is the channel alignment LED

LED3 is the data valid LED

LED4 indicates that the test is running

LED5 is the error signal

4.

Press stop (GX PB1) to stop the device from transmitting.