Altera High-Speed Development Kit, Stratix GX Edition User Manual

Page 59

Advertising
background image

Altera Corporation

Quartus II Version 3.0

5–15

Perform the Production Diagnostic Tests

Perform the Standard Tests

6.

Press the stop pushbutton switch (Stratix_GX_PB1) to stop the
device from transmitting.

7.

Press the reset pushbutton switch (GX_CLR).

8.

Press the start pushbutton switch (Stratix_GX_PB_0).

9.

Inject an error by pressing Stratix_GX_PB_2 (S4) once. The number
01 displays on the Stratix GX 7-segment display (D9) and Stratix GX
LED5 illuminates.

10. Inject two more errors by pressing Stratix_GX_PB_2 (S4) twice. 03

displays on the Stratix GX 7-segment display (D9).

11. Press start and then reset three times to insure that the test is

working.

12. If all of these tests pass, write the word “PASS” in the column under

Stratix GX in the row Stratix GX HM-Zd (SPI 4.2) in the worksheet.

Source Synchronous DPA SMA interface (Stratix GX SMA DPA)

For this test, perform the following steps in the Programmer.

1.

Click Auto-Detect to display all of the devices in the JTAG chain.

2.

Change the programming file for the Stratix GX device to
GX40_SS_DPA.sof

. Wait until the checksum field is updated.

3.

Turn on the Program/Configure option for the Stratix GX device.

Figure 5–18 shows the Programmer after you have done these steps.

Advertising