Test setup, Run the stratix gx ddr sdram interface test – Altera High-Speed Development Kit, Stratix GX Edition User Manual

Page 34

Advertising
background image

4–6

Quartus II Version 3.0

Altera Corporation

Stratix GX DDR SDRAM Interface

High-Speed Development Kit, Stratix GX Edition User Guide

Test Setup

Perform the following steps to set up the test.

1.

Remove power from the board.

2.

Insert the DDR DIMM module in the location defined in Figure 4–3.

Figure 4–3. Inserting DDR DIMM

3.

Attach one end of the RS-232 cable to your PC’s COM 1 port and the
other end to the bottom connector of the RS-232 serial port on the
board.

4.

Set the board’s switches as shown in Table 4–1 for this test.

5.

Supply power to the board.

6.

Confirm that the Stratix GX device has finished configuration (the
GX_CONF_DONE (D7) LED illuminates).

Run the Stratix GX DDR SDRAM Interface Test

Perform the following steps to run the test.

1.

Choose Programs > Altera > SOPC Builder <version> > SOPC
Builder SDK Shell

(Windows Start menu).

1

This shell may be named Nios SDK Shell in older versions
of the Nios embedded processor.

2.

Change to the Nios SOFs directory by typing the following
command:

cd /Stratix_GX_kit/Test_designs/Nios_test_designs/

Nios_sofs

r

3.

Type

nr -t

r to open a terminal window that connects to COM 1.