Altera High-Speed Development Kit, Stratix GX Edition User Manual

Page 78

Advertising
background image

5–34

Quartus II Version 3.0

Altera Corporation

Nios-Based Tests

High-Speed Development Kit, Stratix GX Edition User Guide

10. Confirm that you are connected to the Nios processor running on

the board by pressing the Enter key a few times in the terminal
window to display the processor's memory contents.

11. Exit the terminal window by pressing the Ctrl + C keys.

12. Type

nr idemon.srec

r to start the Compact Flash test. Observe

the results to see if any errors are reported. Figure 5–25 shows the
text that should display in the shell.

Figure 5–25. Compact Flash Test Results

[SOPC Builder]$ nr idemon.srec
nios-run: Ready to download idemon.srec over COM1: at 115200 bps
niosrun:Downloading.....................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................
........................................................................................

nios-run: Terminal mode (Control-C exits)
-----------------------------------------
IDE Monitor v 1.1alpha
Starting Comprehensive CF Test!
Getting Compact Flash Params:
Param Returns:
Cylinders: 496
Heads: 4
Sectors: 32

Starting Test:
Completed Testing of 20 Cylinders
Completed Testing of 40 Cylinders
Completed Testing of 60 Cylinders
Completed Testing of 80 Cylinders
Completed Testing of 100 Cylinders
Completed Testing of 120 Cylinders
Completed Testing of 140 Cylinders
Completed Testing of 160 Cylinders
Completed Testing of 180 Cylinders
Completed Testing of 200 Cylinders
Completed Testing of 220 Cylinders

Advertising