Perform the Production Diagnostic Tests

Perform the Standard Tests

4.

Press the stop pushbutton switch (GX PB1) to stop the device from
transmitting.

5.

Press the reset pushbutton switch (GX_CLR).

6.

Press the start pushbutton switch (Stratix_GX_PB_0).

7.

Inject an error by pressing Stratix_GX_PB_2 (S4) once. The number
01 displays on the Stratix GX 7-segment display (D9) and Stratix GX
LED5 illuminates.

8.

Inject two more errors by pressing Stratix_GX_PB_2 (S4) twice. 03
displays on the Stratix GX 7-segment display (D9).

9.

Press start and then reset three times to insure that the test is
working.

10. If all of these tests pass, write the word “PASS” in the column under

Stratix GX in the row Stratix GX HM-Zd XCVR in the spreadsheet.

Gigabit Transceivers with SFP Interface (Stratix GX SFP XCVR)

For this test, perform the following steps.

1.

Change the XCVR setting to SFP by setting the Stratix GX user
dipswitch 6 to the down position and dipswitch 5 to the down
position.

2.

Press the reset pushbutton switch (GX_DEV CLR) to initialize the
design. The GX_DEV_CLR LED illuminates.

3.

Press the start pushbutton switch (GX PB0). The LED for channel 0
(LED0) illuminates.

4.

Press start and then reset several times to insure that the test is
working. LED0, LED1, LED2, and LED3 are the match lights on a
per channel basis.

5.

Press the reset pushbutton switch.

6.

Remove the SFP card.

7.

Re-attach the card in the connector at J64.

8.

Press the start pushbutton switch. LED1 illuminates if the test is
successful.