Ertd errors, File server – Daktronics Show Control System User Manual

Page 140

Advertising
background image

133

Daktronics Show Control System

Troubleshooting

Likely Reason:

The Show Control Server is not on; likely due to network issues.

Potential solution: Verify that the Show Control Server is running. Ensure that both the Show Control

Client and Server have a network connection and can ping each other.

Message:

Unknown Error Contacting the Server. Make sure “Daktronics Nucleus Server”
is running on the Server Machine.

Likely Reason:

The Nucleus Server service is not running on the Show Control Server.

Potential solution: Manually start the Nucleus Server service on the Show Control Server and ensure

that it is set to start automatically.

Message:

Error Authenticating Client Credentials. Make sure that the Client and Server
are set to the same time (GMT).

Likely Reason:

The clocks on the Show Control Client and Show Control Server are not
synchronized. The clocks must be set for the same time, to within five minutes.

Potential solution: Synchronize the clocks on the two machines.

Message:

Error contacting the Show Control database. Make sure the SQL Server
(Nucleus) is running on the Server machine.

Likely Reason:

The SQL Server (NUCLEUS) service is not running on the Show Control Server.

Potential solution: Manually start the SQL Server (NUCLEUS) service on the Show Control Server and

ensure that it is set to start automatically.

ERTD errors

Message:

The following signs share Id=<ERTD ID> : <Sign 1>, <Sign 2>, …

Likely Reason:

Multiple signs are configured with the same ERTD sign number.

Potential solution: If this is the desired configuration, click Ignore. Otherwise, edit the ERTD number of

the signs so that they all have unique sign numbers.

Message:

The following signs have an ERTD Id=0 : <Sign 1>, <Sign 2>, …

Likely Reason:

There are one or more signs with an ERTD number of 0.

Potential solution: If this is the desired configuration, click Ignore. Otherwise, edit the ERTD number of

the signs so they are unique and not 0.

File Server

Message:

No file servers detected. Please check the player configuration.

Likely Reason:

The DMP-7000 File Server(s) are not configured with their full UNC path(es).

Potential solution: Add the DMP-7000 file server(s) to the Venus 7000 Shell System Configuration.

Ensure that the full UNC path is entered (\\[Computer Name]\V7000)