Daktronics Show Control System

Troubleshooting

Message:

Cannot find network path <File Server Path>. Check that network is
accessible, the path exists, and the player is configured properly.

Likely Reason:

On the affected DMP-7000 machine, the C:\V7000 (or D:\V7000) folder is not
configured to be shared.

Potential solution: On the affected DMP-7000 machine, set the V7000 folder to be shared with

permissions to allow network users to change files.

Message:

Error writing to network path <File Server Path>. Check that permissions are
set correctly.

Likely Reason:

On the affected DMP-7000 machine, the C:\V7000 (or D:\V7000) folder does not
have proper access permissions configured.

Potential solution: On the affected DMP-7000 machine, set the network privileges for the V7000

folder. Ensure that network users are allowed to change files.

Venus 7000 (DMP-7000)

Message:

Not Responding.

Likely Reason:

The affected DMP-7000 machine is not running or is experiencing network issues.

Potential solution: Make sure the affected DMP-7000 machine is running; that both it and the Show

Control user station are connected to the network; and that they can ping each
other. If the problem persists, it could be a DNS issue. Contact your IT
administrator.

Message:

Imaging Service Not Responding.

Likely Reason:

The V7CPP Imaging Service service is not running on the affected machine.

Potential solution: Manually start the V7CPP Imaging Service on the affected machine and ensure that

it is set to start automatically.

Message:

No Venus 7000 Services.

Likely Reason:

The Venus 7000 Sign service is not running or the V7000 account has been
removed from either the affected DMP-7000 machine or the Show Control user
station.

Potential solution: Ensure that the Venus 7000 Sign service is started and set to start automatically and

confirm that the machines have matching usernames and passwords.

DMP-8000

Message:

Not Responding.

Likely Reason:

The affected DMP-8000 machine is not running or is experiencing network issues.

Potential solution: Make sure the affected DMP-8000 machine is running; that both it and the Show

Control user station are connected to the network; and that they can ping each
other. If the problem persists, it could be a DNS issue. Contact your IT
administrator.