3.3.7 Input timing

@SHT

Set the total number of horizontal dots

Command
format

@SHT, ch, h_total

Return value
format

@SHT, ch, h_total

Parameter

ch

: Input channel

0 = All analog inputs, 6 = IN6 to 9 = IN9

h_total

: The total number of horizontal dots

400 to 4125 (Sampling clock: 13 MHz to 162 MHz)

[Default]: Differs depending on input signals

Example Send


Receive

@SHT,6,1344


@SHT,6,1344

Set the total number of horizontal dots of IN6
to 1344.
Terminated normally.

Send

Receive

@SHT,6,1344

@ERR,3

If no analog RGB or analog YPbPr signals are
input, an error is replied.

Related info.

8.6.1 The total number of horizontal dots

Note

This command is valid only if analog RGB or analog YPbPr signals are input.

@GHT

Get the total number of horizontal dots

Command
format

@GHT

Return value
format

@GHT, in_1, in_2, in_3, in_4, in_5, in_6, in_7, in_8, in_9

Parameter

in_1-9

: The total number of horizontal dots of each input channel

400 to 4125 (Sampling clock: 13 MHz to 162 MHz)

[Default]: Differs depending on input signals

Example Send

Receive

@GHT

@GHT,2200,2200,0,2640,
1344,1792,0,1792,0

Get the total number of horizontal dots.
0 is replied to channels without input
signals.

Related info.

8.6.1 The total number of horizontal dots