MSD-54 Series Users Guide (Command Guide)

90

Example Send




Receive

@SEC,1,10,3,POW
ER,7,5057204F4E0
D0A,1000,2,500,0,
0,1,2

@SEC,1,10,3,POW
ER,7,5057204F4E0
D0A,1000,2,500,0,
0,1,2

Register to control command 1 as follows:

Delay: 10 ms

Output port: RS-232C CH1 & RS-232C CH2

Memo: POWER

Data size: 7 bytes

Command data : PW ONCR LF (ASCII codes)

Timeout: 1000 ms

Retry: 2 times

Interval: 500 ms

Retry over: Stop

Received data: Not displayed

Replied command: Check 1 and 2

Send




Receive

@SEC,2,0,1024,
IN1 SELECT,10,
405353572C312C3
10D0A,0,0,0,1,0

@SEC,2,0,1024,
IN1 SELECT,10,
405353572C312C3
10D0A,0,0,0,1,0

Register to control command 2 as follows:

Delay: 0ms

Output port: LOOP BACK

Memo: IN1 SELECT

Data size: 10 bytes

Command data: @SSW,1,1CR LF (ASCII codes)

Timeout: 0 ms

Retry: 0 times

Interval: 0 ms

Retry over: Execute

Received data: Not displayed

Replied command: Not checked