MSD-54 Series Users Guide (Command Guide)

80

@GSP

Get speaker configuration

Command
format

@GSP, ch

Return value
format

@GSP, ch, number, speaker_1 (, speaker_2・・・)

Parameter

ch

: Input channel

1 = IN1 to 5 = IN5

number

: Speakers

1 to 8 [Default]: 2

speaker_1-8

: Speakers to be used

0 = Front Left/Right [Default] 1 = Low Frequency Effect,

2 = Front Center, 3 = Rear Left/Right, 4 = Rear Center,

5 = Front Left/Right Center, 6 = Rear Left/Right Center,

7 = Front Left/Right Wide, 8 = Front Left/Right High,

9 = Top Center, 10 = Front Center High

Example Send

Receive

@GSP,1

@GSP,1,6,0,1,2,3

Get speakers of IN1
The following 6 speakers are used: Front
Left/Right, Low Frequency Effect, Front Center,
Rear Left/Right

Related info.

8.9.6 Speaker configuration

@RME Copy

EDID

Command
format

@RME, out, number (, name)

Return value
format

@RME, out, number (, name)

Parameter

out

: Copy connector

1 = OUT1 to 4 = OUT4

number

: number of the saved COPY DATA

1 to 8

name

: Name of “COPY DATA”

Up to 10 characters using 20 to 7D. “2 ASCII codes”

The name of the “COPY DATA” can be pretermitted. If pretermitted, EDID setting is
saved without changing currently saved name.

Example Send


Receive

@RME,1,1


@RME,1,1

Copy the EDID data from the OUT1 monitor and
save to COPY DATA 1.
Terminated normally.

Send


Receive

@RME,3,4,800x600

@RME,3,4,800x600

Copy EDID data of the OUT3 monitor and
save to COPY DATA 4 named “800x600”.
Terminated normally.

Related info.

8.9.7 EDID Copy