MSD-54 Series Users Guide (Command Guide)

96

Example Send

Receive

@GEC,3

@GEC,3,0,512,P
OWER
STATUS,9,
47455420504F57
0D0A,
2000,2,200,0,1,0
D

Get the control command 3.

Delay

:

0

ms

Output port

: LAN 8

Memo

: POWER STATUS

Data size

: 9 bytes

Command data : GET

POWCR LF (ASCII codes)

TimeOUT : 2000 ms

Retry

: 2 times

Interval

: 200 ms

Retry over

: Stop

Received data : Display with ASCII codes

Delimiter

: 0D=Hexadecimals (CR =ASCII

codes)

Send

Receive

@GEC,4

@GEC,4,0,128,I
NPUT,7,
494E53454C0D0
A,2500,4,
100,1,2,100

Get control command 4.

Delay

: 0 ms

Output port

: LAN 6

Memo

: INPUT

Data size

: 7 bytes

Command data : INSELCR LF (ASCII codes)

TimeOUT2500 ms

Retry

: 4 times

Interval

: 100 ms

Retry over

: Execute

Received data : Display with hexadecimals

Replied command : Delimiter not monitored

Related info.

8.12.1 Control commands