IDK MSD-54 Series Command Guide User Manual

Page 98

Advertising
background image

MSD-54 Series Users Guide (Command Guide)

98

@GEC

Get control command (Control Tally output)

Command format

@GEC, no

Return value
format

@GEC, no, delay, port, memo, pinno_1, out_1, pulse_1 (, pinno_2, out_2,
pulse_2, pinno_3

, out_3, pulse_3・・・)

Parameter

no

: Command number

1 to 32

delay

: Delay time

0 to 999999

port

: Tally output control

Specify 2048 for Tally output control.

memo

:

Up to 14 characters of 20 to 7D except 2C (,). “2 ASCII codes”

pinno_1-6

: Pin number

22 to 24, 47 to 49

out_1-6

: Control output pin

0 = OFF, 1 = ON, 2 = TOGGLE

pulse _1-6

: Pulse width

0, 100 to 9990

Send settings of pins you want to control.

Example Send

Receive

@GEC,5

@GEC,5,20,2048,SCREEN
UP, 22,1,100

Get control command 5.

Control after 20 ms.

Memo: SCREEN UP

Tally output pin 22 is ON for 100
ms.

All other pins are not controlled

Send

Receive

@GEC,6

@GEC,6,50,2048,PROJEC
TOR ON,22,0,200,23,1,0

Get control command 6.

Control after 50 ms

Memo: PROJECTOR ON

Tally output pin 22 is OFF for 200
ms.

Tally output pin 23 is ON and the
ON state is kept.

All other pins are not controlled.

Related info.

8.12.1 Control commands