298

NOTE:

A new entry cannot be created if its parameters are identical with the corresponding parameters of an
existing entry. If the created entry is a history entry, it will be compared with the existing history entries
only on the same interface. See

Table 24

for the parameters to be compared for different entries.

The system limits the total number of each type of entries (See

Table 24

for the detailed numbers). When

the total number of an entry reaches the maximum number of entries that can be created, the creation

fails.

Table 24 Restrictions on the configuration of RMON

Entry

Parameters to be compared

Maximum number of

entries that can be created

Event

Event description (description string), event type (log, trap,
logtrap or none) and community name (trap-community or
log-trapcommunity)

60

Alarm

Alarm variable (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute or delta), rising

threshold (threshold-value1) and falling threshold

(threshold-value2)

60

Prialarm

Alarm variable formula (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute, changeratio or
delta), rising threshold (threshold-value1) and falling threshold

(threshold-value2)

50

Displaying and maintaining RMON

To do…

Use the command…

Remarks

Display RMON statistics

display rmon statistics

[ interface-type interface-number ] Available in any view

Display the RMON history control
entry and history sampling
information

display rmon history
[ interface-type interface-number ] Available in any view

Display RMON alarm
configuration information

display rmon alarm
[ entry-number ]

Available in any view

Display RMON prialarm
configuration information

display rmon prialarm
[ entry-number ]

Available in any view

Display RMON events
configuration information

display rmon event
[ entry-number ]

Available in any view

Display log information for the
specified or all event entries

display rmon eventlog
[ entry-number ]

Available in any view

Ethernet statistics group configuration example

Network requirements

As shown in

Figure 92

, SecBlade (SNMP agent) is connected to a configuration terminal through its

console port and to Server through Ethernet cables.