Mdio transactions, Figure 9-1, Table 9-1 – Xilinx 1000BASE-X User Manual

Page 116: Phy1 (mmd), Phy2 (mmd), Mac (sta)

Advertising
background image

116

www.xilinx.com

Ethernet 1000BASE-X PCS/PMA or SGMII v9.1

UG155 March 24, 2008

Chapter 9: Configuration and Status

R

.

The MDIO bus system is a standardized interface for accessing the configuration and
status registers of Ethernet PHY devices. In the example illustrated, the Management Host
Bus I/F of the Ethernet MAC is able to access the configuration and status registers of two
PHY devices via the MDIO bus.

MDIO Transactions

All transactions, read or write, are initiated by the MDIO master. All MDIO slave devices,
when addressed, must respond. MDIO transactions take the form of an MDIO frame,
containing fields for transaction type, address and data. This MDIO frame is transferred
across the MDIO wire synchronously to MDC. The abbreviations are used in this section
are explained in

Table 9-1

.

Figure 9-1:

A Typical MDIO-managed System

Configuration
Registers 0 to 31
(REGAD)

MDIO slave

UG194_5_01_011906

PHY1 (MMD)

Physical
Address
(PHYAD)
= 1

Configuration
Registers 0 to 31
(REGAD)

MDIO slave

PHY2 (MMD)

Physical
Address
(PHYAD)
= 2

MDIO
master

MAC (STA)

MDC

MDIO

Host
Bus I/F

Table 9-1:

Abbreviations and Terms

Abbreviation

Term

PRE

Preamble

ST

Start of frame

OP

Operation code