11. Maintenance and Inspection

110

6) Adjust the belt tension.

Pass a looped strong string (or long tie-band) around the motor cover and pull it with a tension gauge to the

specified tension. In this condition, uniformly tighten the adjustment bolts.

[Recommenced tightening torque for adjustment bolts] (M4) 377 N�cm (38 kgf�cm)

Caution: Carefully tighten them to the specified torque by making sure the

pulleys on both sides do not move.

7) Install the pulley cover.

Tighten the four thin-head screws (M3x6) using an Allen wrench of 1.5 mm across flats.

8) Perform homing using a PC or teaching pendant.

(If the actuator is of absolute encoder specification, an absolute reset must be performed.)

Check for deviation from the initial home position.

If there is a deviation when the SCON controller is being used, use home return offset distance of parameter

No. 22 to make corrections. If the SSEL or the X-SEL controller is being used, use home preset value of axis-

specific parameter No. 12 to make corrections.

For the absolute encoder specification, perform homing � absolute reset after changing the parameter.

Tension: 8 kgf � 0.3 kgf