11. Maintenance and Inspection

152

Encoder

Replacement motor (Encoder by IAI)

Replacement motor (Encoder by Tamagawa)

11.10.5

Replacing the Motor of the Motor Reversing Type: RCS2-SA4R, SA5R, SA6R

[Items Required for Replacement]

Replacement motor

Allen wrenches

Phillips screwdriver

Tension gauge (capable of tensioning to 7 kgf or greater)

Strong string, looped (or long tie-band)

Scale

� Oil-based marker pen

PC or teaching pendant

Caution: When replacing the motor, handle the replacement motor with due care.

The actuator has been shipped with the encode adjusted to an optimal position,

so do not crush the encoder unit. It may displace the encoder, thus impairing

proper actuator operation.