2. Specification
41
(7) Actuator Precision
[1] Actuator installation surface
Parallelism of the actuator installation surface (bottom surface of the base) and load installation surface
(top surface) at an arbitrary stroke position: 0.1 mm or less
[2] Traveling parallelism when the actuator is installed (affixed on a flat, smooth surface
*1
): 0.05 mm/m or
less
Condition: The above values have been measured at 20�C. *1 Parallelism: 0.05 mm/m or less