5. Installation

51

5.4 Installation Surface

The mounting table should have sufficient rigidity to avoid generating vibration.

The surface where the actuator will be mounted should be machined or be equally level and the flatness

tolerance between the actuator and the table should be within � 0.05 mm.

Provide enough space around the actuator to permit maintenance work to be done.

5.4.1

Using Side Faces of the Base as Reference Planes

[RCS2 (CR)]

The side and bottom faces of the actuator base provide the reference planes for slider travel.

When precision is required, use these surfaces as the reference planes for mounting.

Caution: As shown above, the side faces of the base provide the reference planes for

slider travel. When precision is required, use these surfaces as the reference

planes for mounting.

When using the base as the reference planes for mounting the actuator to the machine frame, follow the

machining dimensions shown below.

Type

Dimension A [mm]

SA4

2 to 3

SA5

2 to 4.5

SA6

2 to 4.5

SA7

2 to 5.5

SS7

2 to 4

SS8

2 to 4.5

(side face of the base)

R0.3 or less

Reference plane

(side face of the base)

Reference plane

For position

adjustment