5. Installation
51
�
5.4 Installation Surface
�
The mounting table should have sufficient rigidity to avoid generating vibration.
�
The surface where the actuator will be mounted should be machined or be equally level and the flatness
tolerance between the actuator and the table should be within � 0.05 mm.
�
Provide enough space around the actuator to permit maintenance work to be done.
5.4.1
Using Side Faces of the Base as Reference Planes
[RCS2 (CR)]
�
The side and bottom faces of the actuator base provide the reference planes for slider travel.
�
When precision is required, use these surfaces as the reference planes for mounting.
Caution: As shown above, the side faces of the base provide the reference planes for
slider travel. When precision is required, use these surfaces as the reference
planes for mounting.
When using the base as the reference planes for mounting the actuator to the machine frame, follow the
machining dimensions shown below.
Type
Dimension A [mm]
SA4
2 to 3
SA5
2 to 4.5
SA6
2 to 4.5
SA7
2 to 5.5
SS7
2 to 4
SS8
2 to 4.5
(side face of the base)
R0.3 or less
Reference plane
(side face of the base)
Reference plane
For position
adjustment