11. Maintenance and Inspection

154

[Procedure]

1) Remove the pulley cover using a Phillips screwdriver.

2) Use a Phillips screwdriver to remove the bolts affixing the motor-end cap and attached cables.

3) Pull out the motor-end cap.

Cross recessed screws: M3

Affixing bolts at attached cable

end (Cross recessed screws)

Affixing bolts on motor-end cap

(Cross recessed screws)

Push in the cable end while pulling out

the motor-end cap.

Advertising