11. Maintenance and Inspection

165

8) Adjust the belt tension.

Pass a looped strong string (or long tie-band) around the motor cover and pull it with a tension gauge to the

specified tension. In this condition, uniformly tighten the adjustment bolts.

[Recommenced tightening torque for adjustment bolts] (M4) 377 N�cm (38 kgf�cm)


Caution: Carefully tighten them to the specified torque by making sure the pulleys on both sides do

not move.

9) Install the pulley cover.

Tighten the four thin-head screws (M3x6) using an Allen wrench of 1.5 mm across flats.

10) Perform homing using a PC or teaching pendant.

(If the actuator is of absolute encoder specification, an absolute reset must be performed.)

Check for deviation from the initial home position.

If there is a deviation when the SCON controller is being used, use home return offset distance of

parameter No. 22 to make corrections. If the SSEL or the X-SEL controller is being used, use home preset

value of axis-specific parameter No. 12 to make corrections.

For the absolute encoder specification, perform homing � absolute reset after changing the parameter.

Tension: 8 kgf � 0.3 kgf