IAI America RCS3PCR-SS8C User Manual

Page 195

Advertising
background image



11. Maintenance and Inspection

175

Initial countermark position

Example for SS7R-12/SS8R-10 types:

Turn 90 degrees in the direction of

returning to the mechanical end

(standard home specification).

7) Remove the motor.

Remove the four hexagon socket-head bolts using an Allen wrench of 3 mm across flats.

8) Install the new motor.

Tighten the four hexagon socket-head bolts (M4x15) uniformly using an Allen wrench of 3 mm across flats.
Recommended tightening torque: 176 N�m (18 kgf�cm)

9) Install the motor cover.

Tighten the four hexagon socket-head button bolts (M3x12) using an Allen wrench of 2 mm across flats.

10) Connect the relay connectors for the attached cables, grounding wires etc., back to their original conditions.

Affix the two grounding wires and one shield wire using the flat-head screw and nut.

Connect the relay connectors.

11) Install the motor-end cap.

Tighten the four thin-head screws (M3x6) using an Allen wrench of 1.5 mm across flats.
Caution: Check the storage of cables carefully to make sure the cables are not pinched.

12) Make the adjustment to restore the home position.

Press the slider against the mechanical end on the home side and affix the slider in this position.

� Turn the motor shaft in the direction of returning to the mechanical end (direction of initial check) by the

applicable amount, as specified in the table “Return Angle from Countermark Position,” from the initial

countermark position.

Type

Return angle from

countermark position

SS7R-12 (high speed)

90 degrees

SS7R-6 (medium speed)

180 degrees

SS8R-20 (high speed)

45 degrees

SS8R-10 (medium speed)

90 degrees

Pass the new belt by making sure the pulleys on both sides do not move.

Advertising