11. Maintenance and Inspection

197

22)

Install the motor rear cover of the replacement motor.

23) Use an Allen wench of 2 mm across flats to tighten the motor end cap bolts.

Use a screwdriver to tighten the ground terminal bolt.

24) Use an Allen wench of 2 mm across flats to tighten the screws and install the cover.

Tightening Torque

Ground terminal bolt

Motor end cap bolts

Motor end cap bolt

Tightening torque: 83 N�cm

(8.47 kgf�cm)

Cover mounting bolts