Greasing actuators of cleanroom specification – IAI America RCS3PCR-SS8C User Manual

Page 13

Advertising
background image



Note

Greasing Actuators of Cleanroom Specification

For ROBO Cylinder actuators of cleanroom specification, use grease of low-dust-raising type for

cleanroom applications.

The grease specified in the maintenance/inspection sections of the Operating Manual is for actuators of

standard specification.

Using the grease for the standard actuators on the cleanroom actuators may generate dust.

C Grease by Kuroda Precision Industries is applied to the cleanroom actuators before shipment from

IAI.

Recommended grease: C Grease by Kuroda

Precision Industries Ltd.

No.

Operation

Description

Description

6

Trial Operation Ɣ When the work is carried out with 2 or more persons, make it clear who is

to be the leader and who to be the follower(s) and communicate well with

each other to ensure the safety of the workers.

Ɣ After the teaching or programming operation, perform the check operation

one step by one step and then shift to the automatic operation.

Ɣ When the check operation is to be performed inside the safety protection

fence, perform the check operation using the previously specified work

procedure like the teaching operation.

Ɣ Make sure to perform the programmed operation check at the safety

speed. Failure to do so may result in an accident due to unexpected

motion caused by a program error, etc.

Ɣ Do not touch the terminal block or any of the various setting switches in

the power ON mode. Failure to do so may result in an electric shock or

malfunction.

7

Automatic

Operation

Ɣ Check before starting the automatic operation or rebooting after operation

stop that there is nobody in the safety protection fence.

Ɣ Before starting automatic operation, make sure that all peripheral

equipment is in an automatic-operation-ready state and there is no alarm

indication.

Ɣ Make sure to operate automatic operation start from outside of the safety

protection fence.

Ɣ In the case that there is any abnormal heating, smoke, offensive smell, or

abnormal noise in the product, immediately stop the machine and turn

OFF the power switch. Failure to do so may result in a fire or damage to

the product.

Ɣ When a power failure occurs, turn OFF the power switch. Failure to do so

may cause an injury or damage to the product, due to a sudden motion of

the product in the recovery operation from the power failure.

Advertising