11. Maintenance and Inspection

125

Affixing bolts on motor-end

cap (Cross recessed screws).

Affixing bolts at attached cable

end (Cross recessed screws)

[Procedure]

1) Move the slider to a position where Z-phase turns on (home position).

On both standard actuators and actuators whose home is set on the opposite side, this position corresponds

to 2 mm from the mechanical end.

Warning: If the actuator is installed vertically, move it after turning on the controller power

and forcibly releasing the brake. At this time, beware of danger as the actuator

may drop suddenly.

Always provide a support to brace the actuator hand to prevent sudden drop, so

as not to pinch fingers or damage the work part.

2) Use a Phillips screwdriver to securely tighten the affixing bolts for motor-end cap and actuator cables.

Return the slider 2 mm from

the mechanical end.

Return the slider 2 mm from

the mechanical end.

Draw a countermark with the slider

contacting the mechanical end.

Draw a countermark with the slider

contacting the mechanical end on the

counter-motor side.