7. Setting the Home

62

7. Setting the Home

7.1 Home Return

Home return consists of the following operations:

[1] When a home command is issued, the actuator moves in the direction set by the moving direction

parameter.

[2] The actuator detects the mechanical end via software.

[3] At the mechanical end, the actuator reverses its direction and moves until a Z-phase signal is detected,

where the reference point is set.

[4] The actuator moves further by the offset set by the applicable parameter, and the achieved position is set

as the home.

7.2 Fine-tuning the Home Position

How much the motor should turn after the stopper is contacted until a Z-phase signal generates has been

adjusted prior to shipment. The table below lists standard values set on respective models for the distance

travelled after the slider contacts and reverses its direction at the stopper, until it stops at the home.

Model name

Distance to home from

mechanical stopper or

home sensor (approx.

value in mm)

SA4C, SA5C, SA6C, SA7C, SA4R, SA5R,

SA6R, SA7R, SA8C, SS8C

3 mm

SA4D

2.2 mm

SA5D, SA6D

3 mm

RCS2RCS2CR

SS7C, SS8C, SA7R, SS8R

5 mm

RCS3(P)RCS3(P)CR

SA8C, SA8R, SS8C, SS8R

3 mm

As long as the direction of home return remains the same, the home position of each actuator can be fine-tuned

by changing the parameter. Follow the procedure below to fine-tune the home position:

[1] Perform home return to check the current home.

[2] Next, move to a desired home, check the difference between the two homes, and then correct the home

preset parameter if you are using an XSEL or SSEL controller, or correct the home return offset parameter

if you are using a SCON controller, accordingly.

Add or subtract the difference to/from the value currently set.

[3] If a large offset is specified, the moving range will be reduced by the corresponding amount.

If an offset beyond 1 mm is set, adjust the stroke limits.

7.3 Changing the Direction of Home

To change the direction of home on the delivered actuator, the moving direction parameter, and also the

encoder’s Z-phase on some models, must be adjusted. Consult IAI for details.

Advertising