11. Maintenance and Inspection

113

Tension: SS7R: 6.7 kgf

SS8R: 6.9 kgf

4) Adjust the belt tension.

Pass a looped strong string (or long tie-band) around the motor cover and pull it with a tension gauge to the

specified tension. In this condition, uniformly tighten the adjustment bolts.

Recommenced tightening torque for adjustment bolts

SS7R: 2 upper bolts (M4) 377 N�cm (38 kgf�cm)

2 lower bolts (M4) 377 N�m (38 kgf�cm)

SS8R: 2 upper bolts (M5) 763 N�cm (78 kgf�cm)

2 lower bolts (M4) 377 N�cm (38 kgf�cm)

Caution: Carefully tighten them to the specified torque by making sure the pulleys on both sides do

not move.

5) Install the pulley cover.

With SS7R, tighten the three thin-head screws (M3x6) using an Allen wrench of 1.5 mm across flats. With

SS8R, tighten the three thin-head screws (M4x6) using an Allen wrench of 2 mm across flats.

6) Perform homing using a PC or teaching pendant.

(If the actuator is of absolute encoder specification, an absolute reset must be performed.)

Check for deviation from the initial home position..

If there is a deviation when the SCON controller is being used, use home return offset distance of parameter

No. 22 to make corrections. If the SSEL or the X-SEL controller is being used, use home preset value of axis-

specific parameter No. 12 to make corrections.

For the absolute encoder specification, perform homing � absolute reset after changing the parameter.