Index, Tmer – Yokogawa DAQWORX User Manual

Page 152

Advertising
background image

6-25

IM WX104-01E

1

2

3

4

5

6

7

8

9

Index

Conf

gur

ng the DX1000/DX2000

CH No. and Level

You can assign alarms to annunciator windows by specifying channel numbers and alarm

levels.

You can set [Level] to [1], [2], [3], [4], or [All]. If you select [All], all of the alarms in the

specified channel are assigned to the specified window.

Comment txt block No.

You can select a text string (label) to display in the annunciator window by selecting a

comment text block number.

Tmer

Changes the upper/lower display area

Timer used by event action. Used also in the TLOG computation of the computation

function. The table below shows the number of timers supported by the DX1000 and

DX2000.

Model

Number of Tmers

Models without the multi batch function
(/BT2 option)

4

Models with the multi batch function
(/BT2 option; release number 3 or later)

12

When Usng an Absolute Tmer
• Mode

Select [Absolute].

• Tme nterval

Select the interval from the available settings between 1min to 24h.

• Ref.tme

Set the time in the range of hour 0 to hour 23.

When Usng a Relatve Tmer
• Mode

Select [Relative].

• Tme nterval

Set in the range from 00:01 (1 min.) to 24:00 (24 hours).

Hour: Set in the range from 0 to 24.

Min:

Set in the range from 0 to 59.

• Reset at Math Start

ON Resets the timer when computation is started. The resetting of the timer is not

considered to be a timeout. Even if the timer is used as an event, the action is

not executed.

6.4 Enterng General Settngs

Advertising