6-31

IM WX104-01E

1

2

3

4

5

6

7

8

9

Index

Conf

gur

ng the DX1000/DX2000

Fle name

Set the user-assigned section of the file name. (Up to 16 characters)

Symbols that can be used: #, %, (, ), +, -, ., @, °, and _.

Feld Ttle, Feld Characters

Set text strings. When the multi batch function (/BT2 option; release number 3 or later) is

enabled, select the appropriate batch tab.Title: Up to 20 characters. Characters: Up to 30

characters.The number of fields that you can use is 24 for release number 3 or later and

8 for release number 2 or earlier.

Event Data

Event related settings are enabled when [Data Kind] is set to [E+D] or [Event] in [Basic

Environment] under [Environment] in the [Basic Setting] tab.

Sample rate

Select the data recording interval from the available settings. See the description for “Data

length” on the next page. You cannot specify a sampling rate that is faster than the scan

interval.

Mode

Settngs

Descrpton

Free

Records data continuously.

Single and Repeat

Records data when the trigger condition is met.

You can only select [Free] if you are using the multi batch function (/BT2 option; release

number 3 or later). You can set the multi batch function by setting [Batch operation qty]

under [Environment] - [Detail Setting] in the [Basic setting] tab.

Data length

Select the size of a record data file. The recorded data is divided by the file size

specified here. The available data lengths vary depending on the Sample rate setting.

25 ms*

2

125 ms

250 ms

500 ms

1 s

10 min to

10 min to

10 min to

10 min to

10 min to

4 hours

1 day

2 days

3 days

7 days

2 s

5 s

10 s

30 s

1 min

10 min to

10 min to

10 min to

1 hour to

1 hour to

14 days

31 days

31 days

31 days

31 days

2 min

5 min

10 min

15 min*

3

20 min*

3

1 hour to

1 hour to

1 hour to

1 hour to

1 hour to

31 days

31 days

31 days

31 days

31 days

30 min*

3

1 hour to

31 days

Sample rate*

1

Selectable range

of data length

Sample rate*

1

Selectable range

of data length

Sample rate*

1

Selectable range

of data length

Sample rate*

1

Selectable range

of data length
*1 You cannot choose an interval that is faster than the scan interval.

*2 Selectable on the DX1002, DX1002N, DX1004, DX1004N, DX2004, and DX2008.

*3 Release number 3 or later.

Pre-Trgger

Specify the range when recording data before the trigger condition is met. Select the

range as a percentage of the data length from 0, 5, 25, 50, 75, 95, and 100%. If you do

not want to record the data existing before the trigger condition is met, select 0%.

Trgger Sgnal Key

Select [ON] if you want to activate the trigger using key operation.

6.4 Enterng General Settngs