Conf

gur

ng the MV1000/MV2000

Server Functon

• Use

Select [Use] or [Not] (don’t use).

• Web server Use

For the Web item under Server, select [Use] or [Not] (don’t use). When [Use] is

selected, the Web page item is added to the basic setting mode menu.

• Operator

To set the operator page, select [ON].

• Operator Access Control

To use access control, select [ON]. You must enter a user name and password to

display the operator page. You must select [Login] as [Key Security] or [Comm.

Security] under [Environment] - [Detail Setting] in the [Basic Setting] tab, and

register users under the [User Registration].

• Command

To write messages, select [ON]; Otherwise, select [OFF].

• Montor

To display the monitor page on a browser, select [ON]; otherwise, select [OFF].

• Montor Access Control

Same as the Operator Access Control.

• SNTP Server Use

select [Use] or [Not] (don’t use).

• Modbus Server Use

select [Use] or [Not] (don’t use).