H led codes, Processor failure codes – HP Remote Assistant Card User Manual

Page 173

Advertising
background image

155

H LED Codes

These tables list the error codes which will be flashed on the LED to indicate problems
with the HP Remote Assistant EISA Board. (Only the first failure found will be
reported.)

Each failure is stored as a 4 BCD digit code. Only the three leading digits will be
flashed. This will allow each code to have up to 10 "sub-codes" which can be
presented by the diagnostic utility. To get detailed error codes, run the DOS-based
diagnostic utility on the HP Remote Assistant Server Disk, by typing:
A:\HPRADIAG\POSTREP.EXE.

LED codes are flashed in the following sequence:

1. OFF for several seconds.

2. One long ON pulse.

3. Three sets of short ON pulses indicating the error codes.

4. Repeat 1 through 3 indefinitely.

For example, a 1-3-2 error would appear as: a long OFF, a long ON, flash, pause,
flash-flash-flash, pause, flash-flash.

Processor Failure Codes

PROCESSOR Failure Codes

LED
Code

REPORT
codes

Failure Name

Failure Reason

Possible Cause

none
LED off

none

PROCESSOR NOT
RUNNING

Processor fails test of
internal registers and
cannot operate.
Processor halted

Defective
Microprocessor
(U40) Defective
oscillator (Y10)

Advertising