HP Remote Assistant Card User Manual

Page 180

Advertising
background image

H LED Codes

162

UART Failure Codes

LED
Code

REPORT
codes

Failure Name

Failure Reason

Possible
Cause

2-2-1

2210

UART Register R/W Failure

Register cannot be
programmed correctly

2-2-2

2220

UART FIFO Failure

UART FIFO control

register not working

Defective
UART (U60)

2-2-3

2230

UART Data Loopback Failure

Couldn't successfully
loop back data

2231

UART Data Loopback Timeout

2-2-4

2240

UART Control Loopback
Failure

Couldn't successfully
loop back controls

A to D CONVERTER Failure Codes

LED
Code

REPORT
codes

Failure Name

Failure Reason

Possible
Cause

2-3-1

2310

+5 Volt Reading Above Limit

2311

+5 Volt Reading Below Limit

2-3-2

2320

+12 Volt Reading Above Limit

Reading obtained

outside of set limits

Defective AtoD
Converter (U84)

2321

+12 Volt Reading Below Limit

2-3-3

2331

-12 Volt Reading Above Limit

2332

-12 Volt Reading Below Limit

2-3-4

2340

Internal Temperature Reading

Above Limit

Reading obtained
outside of set limits

Defective AtoD
Converter (U84)

2341

Internal Temperature Reading
Below Limit

Defective temp
sensor (U85)

2-3-5

2350

ADC Timeout

AtoD didn't finish
conversion within
timeout period

Defective AtoD
Converter (U84)

Advertising