Lldp reinit, Lldp reinit <1-10 – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 1941

LLDP Commands
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
71.15
lldp reinit
This command sets the value of the reinitialization delay. This is the minimum time after
disabling LLDP on a port before it can reinitialize.
The no variant of this command sets the reinitialization delay back to its default setting.
Syntax
lldp reinit <1-10>
no lldp reinit
Default
The default reinitialization delay is 2 seconds.
Mode
Global Configuration
Examples
To set the reinitialization delay to 3 seconds, use the commands:
To set the reinitialization delay back to its default, use the commands:
Related Commands
Parameter
Description
<1-10>
The delay in seconds.
awplus#
configure terminal
awplus(config)#
lldp reinit 3
awplus#
configure terminal
awplus(config)#
no lldp reinit