77.17
Examples
To allow trigger 63 to activate between midnight and 10:30am, use the commands:
To allow trigger 64 to activate between 3:45pm and midnight, use the commands:
To allow trigger 65 to activate between 10:30am and 8:15pm, use the commands:
Related Commands
awplus#
configure terminal
awplus(config)#
trigger 63
awplus(config-trigger)#
time before 10:30:00
awplus#
configure terminal
awplus(config)#
trigger 64
awplus(config-trigger)#
time after 15:45:00
awplus#
configure terminal
awplus(config)#
trigger 65
awplus(config-trigger)#
time after 10:30:00 before 20:15:00