Clear loop-protection counters – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 365

Switching Commands
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
15.3
To disable back pressure flow control on interface port1.0.2 enter the following
commands:
Validation
Commands
show running-config
show interface
Related Commands
clear loop-protection counters
Use this command to clear the counters for the Loop Protection counters.
Syntax
clear loop-protection [interface <port-list>] counters
Mode
Privileged Exec
Examples
To clear the counter information:
awplus#
configure terminal
awplus(config)#
interface port1.0.2
awplus(config-if)#
backpressure off
Parameters
Description
interface
The interface whose counters are to be cleared.
<port-list>
A port, a port range, or an aggregated link.
awplus#
clear loop-protection counters
awplus#
clear loop-protection interface port1.0.1 counters