sFlow Introduction and Configuration
Software Reference for x310 Series Switches
80.12
AlliedWare Plus
TM
Operating System - Version 5.4.4C
C613-50046-01 REV A
Step 4:
Check the Configuration
View the sFlow Configuration
awplus#
do show running-config sflow
Validate that sFlow is enabled
Note that the prefix “do” enables you to run
an Exec Mode command from an Interface
Mode prompt.
Figure 80-3: Output from the show-running config sFlow command
awplus#sh run sflow
!
sflow agent ip 192.0.2.33
sflow collector ip 192.0.2.65
sflow collector max-datagram-size 1200
sflow enable
!
interface port1.0.13-port1.0.22
sflow sampling-rate 2750